home *** CD-ROM | disk | FTP | other *** search
/ Night Owl 9 / Night Owl CD-ROM (NOPV9) (Night Owl Publisher) (1993).ISO / 038a / zhint55.exe / S95 < prev    next >
Text File  |  1993-04-08  |  2KB  |  31 lines

  1.                                S95 Register
  2.  
  3.      By  default  S95=0 gives the computer-modem (DTE)  connect  speed.  So
  4. whatever  speed  (19,200   38,400   57,600) you have set,  the  modem  will
  5. respond  in kind, even if the modem-modem connect is 2400. S95=1 will  give
  6. true  modem-modem connect speed (DCE), ie; a 2400 CARRIER will say  CONNECT
  7. 2400.  S95=2 will add /Arq to default for error correction conections,  ie;
  8. CONNECT  19,200/Arq.  S95=3 will give modem connect speed  with  /Arq   ie;
  9. CONNECT 2400/Arq. If your software recognizes /Arq it may be a good idea to
  10. add it, via the S95 register.
  11.  
  12. >>>NOTE:  When the modem gives DTE (computer-modem) connect speed, if  your
  13. software shows 'efficiency' of transfer, it will be LOW. If the modem sends
  14. CARRIER  (DCE)  as connect speed, then 'shown' efficiency  should  approach
  15. 100%.
  16.  
  17.      If  you  want the Carrier, Protocol & Compression, with DTE  then  use
  18. S95=44. To get the same with DCE speed, use S95=45. You can add 2 to either
  19. (46  or  47)  which will add the /ARQ, but as you already  have  the  other
  20. messages it is redundant.
  21.  
  22.      The  default S36=7 enables buffering so that the modem-computer  speed
  23. may differ from the modem-modem speed.
  24.  
  25. >>NOTE<<  Except for QMODEM, all the sofware I have seen does NOT show  any
  26. results  beyond  CONNECT  xxx/ARQ.  You  can see  the  results  if  you  do
  27. ATDTphoneumber in Terminal mode.
  28.  
  29.                                    Don Hinds - Zoom Tech
  30. ##include=c:\text\signa.tif